Time on an Embedded Device

Introduction

For a device to keep correct time with Qt Extended requires the following:

  1. the kernel must support a Real-Time Clock (RTC) interface and be built with the correct driver for the device RTC.
  2. the Linux distribution must contain /sbin/hwclock that accepts the -s and -w parameters.
  3. boot scripts set system-time from hardware-time on startup /sbin/hwclock -s.

Note: These processes should be tested on the device prior to Qt Extended controlling them.

External Time Sources

Devices may that have readily available external time sources, such as:

  • GSM Cell Tower Time
  • NTP IP Network Time

Such devices should report such updates by sending a storeExternalSource(QString,uint,int,int) message to the TimeUpdate service.

Currently, only one external source is supported.

If no external source is available, the user will need to set the time shortly after start-up, and the RTC will need to be sufficiently reliable.

Install Required Time Conversion files

Qt Extended requires Time Conversion data such as in <qt-extended-root-dir>/etc/zoneinfo to be on the device. To install the Time Conversion data files either:

  1. Create a symbolic link to the Time Conversion data files provided by Qt Extended, for example, on the device run:
        if [ ! -d /usr/share/zoneinfo ]; then ln -s /opt/Qtopia/etc/zoneinfo /usr/share/zoneinfo; fi
  2. Create a symbolic link to the Time Conversion data files provided by the device's environment, for example, on the device run:
        if [ -d /usr/share/zoneinfo ]; then rm -rf /opt/Qtopia/etc/zoneinfo; ln -s /usr/share/zoneinfo /opt/Qtopia/etc/zoneinfo ; fi
  3. If the Time Conversion data cannot be uploaded to the device's root file system modify the value of QTOPIA_ZONEINFO_PATH in the device's custom.h to point to where the Time Conversion data files are stored.

Cette page est une traduction d'une page de la documentation de Qt, écrite par Nokia Corporation and/or its subsidiary(-ies). Les éventuels problèmes résultant d'une mauvaise traduction ne sont pas imputables à Nokia. Qt qtextended4.4
Copyright © 2012 Developpez LLC. Tous droits réservés Developpez LLC. Aucune reproduction, même partielle, ne peut être faite de ce site et de l'ensemble de son contenu : textes, documents et images sans l'autorisation expresse de Developpez LLC. Sinon, vous encourez selon la loi jusqu'à 3 ans de prison et jusqu'à 300 000 E de dommages et intérêts. Cette page est déposée à la SACD.